FLAMEX SI EN 50382-2 3600V 185 FX 120°C

Description

Description

Standards

  • Product
    EN 45545-2 (HL3); EN 50382-2; IEC 60228

FLAMEX® EN 50382-2 FX power cables are designed with extra flexible conductors for easier installation. Able to withstand higher operating temperatures, these silicone-based cables allow to save cable weight.

DESIGN

1. Conductor
Extra flexible class 6 copper according to IEC 60228
    - tinned copper for 120°C Class
    - plain copper for 150°C Class
Separator: Unweaved tape

2. Insulation
Cross-linked silicone type EI 111 according to EN 50382-1
Colour: black outer layer

Example of marking: FLAMEX SI - EN 50382-2 - Voltage rate (1800V or 3600V) - cross-section mm² - FX - temperature class (150°C) - LYNXEO 279 - week/year

 

FIRE SAFETY

FLAMEX® EN 50382-2 FX power cables are conform to EN 45545-2 HL3

 

GUIDE TO USE

  • Cabling rules are given in EN 50343 and EN 50355
  • Permissible current carrying capacities: values and calculation method are given in EN 50343
  • Bending radius:
    • Static use: 4 x outer cable diameter
    • For installation and occasional movements: 6 x outer cable diameter
  • Pulling tensible force (dynamic) during installation: 50 N/mm² of copper size
  • Mechanical static tensible force: 15N/mm² of copper size

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Tin plated copper
Conductor flexibility
Extra-flexible class 6
Insulation
High temperature silicone
Halogen free
EN 60754-1 & EN 60684-2

Dimensional characteristics

Dimensional characteristics

Conductor cross-section
185 mm²
Conductor diameter
17.5 mm
Nominal outer diameter
24.6 mm
Minimum outer diameter
22.6 mm
Maximum outer diameter
26.5 mm
Approximate weight
1839 kg/km

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
3.6 / 6 (7.2) kV

Usage characteristics

Usage characteristics

Flame retardant
EN 60332-1-2
Fire retardant
EN IEC 60332-3-24 (cat C); EN IEC 60332-3-25 (EN50305)
Smoke density
EN/IEC 61034-2
Gases toxicity
EN 50305-9.2
Operating temperature, range
-50 ... 120 °C
Max. conductor temperature in service
120 °C
Overload maximum core temperature
140 °C
Chemical resistance
Good

Resources

Resources

Documentation

FLAMEX SI type F png — 9.5 kB

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close