FLAMEX SI EN 50382-2 1800V 10 FX 120°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Tin plated copper
- Conductor cross-section: 10 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
- Max. conductor temperature in service: 120 °C
- Overload maximum core temperature: 140 °C
FLAMEX SI EN 50382-2 1800V 10 FX 150°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Plain copper
- Conductor cross-section: 10 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
- Max. conductor temperature in service: 150 °C
- Overload maximum core temperature: 170 °C
FLAMEX SI EN 50382-2 1800V 120 FX 120°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Tin plated copper
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 20.0 mm
- Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
- Max. conductor temperature in service: 120 °C
- Overload maximum core temperature: 140 °C
FLAMEX SI EN 50382-2 1800V 120 FX 150°C
Nexans ref. 10227163
- Packaging: Drum (1000m)
- Conductor material: Plain copper
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 20.0 mm
- Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
- Max. conductor temperature in service: 150 °C
- Overload maximum core temperature: 170 °C
FLAMEX SI EN 50382-2 1800V 150 FX 120°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Tin plated copper
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 22.5 mm
- Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
- Max. conductor temperature in service: 120 °C
- Overload maximum core temperature: 140 °C
FLAMEX SI EN 50382-2 1800V 150 FX 150°C
Nexans ref. 10263103
- Packaging: Drum (1000m)
- Conductor material: Plain copper
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 22.5 mm
- Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
- Max. conductor temperature in service: 150 °C
- Overload maximum core temperature: 170 °C
FLAMEX SI EN 50382-2 1800V 16 FX 120°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Tin plated copper
- Conductor cross-section: 16 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
- Max. conductor temperature in service: 120 °C
- Overload maximum core temperature: 140 °C
FLAMEX SI EN 50382-2 1800V 16 FX 150°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Plain copper
- Conductor cross-section: 16 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
- Max. conductor temperature in service: 150 °C
- Overload maximum core temperature: 170 °C
FLAMEX SI EN 50382-2 1800V 185 FX 120°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Tin plated copper
- Conductor cross-section: 185 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
- Max. conductor temperature in service: 120 °C
- Overload maximum core temperature: 140 °C
FLAMEX SI EN 50382-2 1800V 185 FX 150°C
Nexans ref. 10263125
- Packaging: Drum (1000m)
- Conductor material: Plain copper
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 23.8 mm
- Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
- Max. conductor temperature in service: 150 °C
- Overload maximum core temperature: 170 °C
FLAMEX SI EN 50382-2 1800V 2.5 FX 120°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Tin plated copper
- Conductor cross-section: 2.5 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
- Max. conductor temperature in service: 120 °C
- Overload maximum core temperature: 140 °C
FLAMEX SI EN 50382-2 1800V 2.5 FX 150°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Plain copper
- Conductor cross-section: 2.5 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
- Max. conductor temperature in service: 150 °C
- Overload maximum core temperature: 170 °C
FLAMEX SI EN 50382-2 1800V 240 FX 120°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Tin plated copper
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 26.7 mm
- Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
- Max. conductor temperature in service: 120 °C
- Overload maximum core temperature: 140 °C
FLAMEX SI EN 50382-2 1800V 240 FX 150°C
Nexans ref. 10227162
- Packaging: Drum (1000m)
- Conductor material: Plain copper
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 26.7 mm
- Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
- Max. conductor temperature in service: 150 °C
- Overload maximum core temperature: 170 °C
FLAMEX SI EN 50382-2 1800V 25 FX 120°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Tin plated copper
- Conductor cross-section: 25 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
- Max. conductor temperature in service: 120 °C
- Overload maximum core temperature: 140 °C
FLAMEX SI EN 50382-2 1800V 25 FX 150°C
Nexans ref. 10261507
- Packaging: Drum (1000m)
- Conductor material: Plain copper
- Conductor cross-section: 25 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
- Max. conductor temperature in service: 150 °C
- Overload maximum core temperature: 170 °C
FLAMEX SI EN 50382-2 1800V 300 FX 120°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Tin plated copper
- Conductor cross-section: 300 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
- Max. conductor temperature in service: 120 °C
- Overload maximum core temperature: 140 °C
FLAMEX SI EN 50382-2 1800V 300 FX 150°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Plain copper
- Conductor cross-section: 300 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
- Max. conductor temperature in service: 150 °C
- Overload maximum core temperature: 170 °C
FLAMEX SI EN 50382-2 1800V 35 FX 120°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Tin plated copper
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 13.1 mm
- Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
- Max. conductor temperature in service: 120 °C
- Overload maximum core temperature: 140 °C
FLAMEX SI EN 50382-2 1800V 35 FX 150°C
Nexans ref. 10261508
- Packaging: Drum (1000m)
- Conductor material: Plain copper
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 13.1 mm
- Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
- Max. conductor temperature in service: 150 °C
- Overload maximum core temperature: 170 °C
FLAMEX SI EN 50382-2 1800V 4 FX 120°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Tin plated copper
- Conductor cross-section: 4 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
- Max. conductor temperature in service: 120 °C
- Overload maximum core temperature: 140 °C
FLAMEX SI EN 50382-2 1800V 4 FX 150°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Plain copper
- Conductor cross-section: 4 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
- Max. conductor temperature in service: 150 °C
- Overload maximum core temperature: 170 °C
FLAMEX SI EN 50382-2 1800V 400 FX 120°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Tin plated copper
- Conductor cross-section: 400 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
- Max. conductor temperature in service: 120 °C
- Overload maximum core temperature: 140 °C
FLAMEX SI EN 50382-2 1800V 400 FX 150°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Plain copper
- Conductor cross-section: 400 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
- Max. conductor temperature in service: 150 °C
- Overload maximum core temperature: 170 °C
FLAMEX SI EN 50382-2 1800V 50 FX 120°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Tin plated copper
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 14.4 mm
- Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
- Max. conductor temperature in service: 120 °C
- Overload maximum core temperature: 140 °C
FLAMEX SI EN 50382-2 1800V 50 FX 150°C
Nexans ref. 10263100
- Packaging: Drum (1000m)
- Conductor material: Plain copper
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 14.4 mm
- Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
- Max. conductor temperature in service: 150 °C
- Overload maximum core temperature: 170 °C
FLAMEX SI EN 50382-2 1800V 6 FX 120°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Tin plated copper
- Conductor cross-section: 6 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
- Max. conductor temperature in service: 120 °C
- Overload maximum core temperature: 140 °C
FLAMEX SI EN 50382-2 1800V 6 FX 150°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Plain copper
- Conductor cross-section: 6 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
- Max. conductor temperature in service: 150 °C
- Overload maximum core temperature: 170 °C
FLAMEX SI EN 50382-2 1800V 70 FX 120°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Tin plated copper
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 16.4 mm
- Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
- Max. conductor temperature in service: 120 °C
- Overload maximum core temperature: 140 °C
FLAMEX SI EN 50382-2 1800V 70 FX 150°C
Nexans ref. 10263101
- Packaging: Drum (1000m)
- Conductor material: Plain copper
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 16.4 mm
- Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
- Max. conductor temperature in service: 150 °C
- Overload maximum core temperature: 170 °C
FLAMEX SI EN 50382-2 1800V 95 FX 120°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Tin plated copper
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 18.3 mm
- Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
- Max. conductor temperature in service: 120 °C
- Overload maximum core temperature: 140 °C
FLAMEX SI EN 50382-2 1800V 95 FX 150°C
Nexans ref. 10263102
- Packaging: Drum (1000m)
- Conductor material: Plain copper
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 18.3 mm
- Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
- Max. conductor temperature in service: 150 °C
- Overload maximum core temperature: 170 °C
FLAMEX SI EN 50382-2 3600V 10 FX 120°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Tin plated copper
- Conductor cross-section: 10 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Max. conductor temperature in service: 120 °C
- Overload maximum core temperature: 140 °C
FLAMEX SI EN 50382-2 3600V 10 FX 150°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Plain copper
- Conductor cross-section: 10 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Max. conductor temperature in service: 150 °C
- Overload maximum core temperature: 170 °C
FLAMEX SI EN 50382-2 3600V 120 FX 120°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Tin plated copper
- Conductor cross-section: 120 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Max. conductor temperature in service: 120 °C
- Overload maximum core temperature: 140 °C
FLAMEX SI EN 50382-2 3600V 120 FX 150°C
Nexans ref. 10263130
- Packaging: Drum (1000m)
- Conductor material: Plain copper
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 21.0 mm
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Max. conductor temperature in service: 150 °C
- Overload maximum core temperature: 170 °C
FLAMEX SI EN 50382-2 3600V 150 FX 120°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Tin plated copper
- Conductor cross-section: 150 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Max. conductor temperature in service: 120 °C
- Overload maximum core temperature: 140 °C
FLAMEX SI EN 50382-2 3600V 150 FX 150°C
Nexans ref. 10263131
- Packaging: Drum (1000m)
- Conductor material: Plain copper
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 22.3 mm
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Max. conductor temperature in service: 150 °C
- Overload maximum core temperature: 170 °C
FLAMEX SI EN 50382-2 3600V 16 FX 120°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Tin plated copper
- Conductor cross-section: 16 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Max. conductor temperature in service: 120 °C
- Overload maximum core temperature: 140 °C
FLAMEX SI EN 50382-2 3600V 16 FX 150°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Plain copper
- Conductor cross-section: 16 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Max. conductor temperature in service: 150 °C
- Overload maximum core temperature: 170 °C
FLAMEX SI EN 50382-2 3600V 185 FX 120°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Tin plated copper
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 24.6 mm
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Max. conductor temperature in service: 120 °C
- Overload maximum core temperature: 140 °C
FLAMEX SI EN 50382-2 3600V 185 FX 150°C
Nexans ref. 10227377
- Packaging: Drum (1000m)
- Conductor material: Plain copper
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 24.6 mm
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Max. conductor temperature in service: 150 °C
- Overload maximum core temperature: 170 °C
FLAMEX SI EN 50382-2 3600V 2.5 FX 120°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Tin plated copper
- Conductor cross-section: 2.5 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Max. conductor temperature in service: 120 °C
- Overload maximum core temperature: 140 °C
FLAMEX SI EN 50382-2 3600V 2.5 FX 150°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Plain copper
- Conductor cross-section: 2.5 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Max. conductor temperature in service: 150 °C
- Overload maximum core temperature: 170 °C
FLAMEX SI EN 50382-2 3600V 240 FX 120°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Tin plated copper
- Conductor cross-section: 240 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Max. conductor temperature in service: 120 °C
- Overload maximum core temperature: 140 °C
FLAMEX SI EN 50382-2 3600V 240 FX 150°C
Nexans ref. 10263132
- Packaging: Drum (1000m)
- Conductor material: Plain copper
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 28.3 mm
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Max. conductor temperature in service: 150 °C
- Overload maximum core temperature: 170 °C
FLAMEX SI EN 50382-2 3600V 25 FX 120°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Tin plated copper
- Conductor cross-section: 25 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Max. conductor temperature in service: 120 °C
- Overload maximum core temperature: 140 °C
FLAMEX SI EN 50382-2 3600V 25 FX 150°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Plain copper
- Conductor cross-section: 25 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Max. conductor temperature in service: 150 °C
- Overload maximum core temperature: 170 °C
FLAMEX SI EN 50382-2 3600V 300 FX 120°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Tin plated copper
- Conductor cross-section: 300 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Max. conductor temperature in service: 120 °C
- Overload maximum core temperature: 140 °C
FLAMEX SI EN 50382-2 3600V 300 FX 150°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Plain copper
- Conductor cross-section: 300 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Max. conductor temperature in service: 150 °C
- Overload maximum core temperature: 170 °C
FLAMEX SI EN 50382-2 3600V 35 FX 120°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Tin plated copper
- Conductor cross-section: 35 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Max. conductor temperature in service: 120 °C
- Overload maximum core temperature: 140 °C
FLAMEX SI EN 50382-2 3600V 35 FX 150°C
Nexans ref. 10263126
- Packaging: Drum (1000m)
- Conductor material: Plain copper
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 14.0 mm
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Max. conductor temperature in service: 150 °C
- Overload maximum core temperature: 170 °C
FLAMEX SI EN 50382-2 3600V 4 FX 120°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Tin plated copper
- Conductor cross-section: 4 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Max. conductor temperature in service: 120 °C
- Overload maximum core temperature: 140 °C
FLAMEX SI EN 50382-2 3600V 4 FX 150°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Plain copper
- Conductor cross-section: 4 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Max. conductor temperature in service: 150 °C
- Overload maximum core temperature: 170 °C
FLAMEX SI EN 50382-2 3600V 400 FX 120°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Tin plated copper
- Conductor cross-section: 400 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Max. conductor temperature in service: 120 °C
- Overload maximum core temperature: 140 °C
FLAMEX SI EN 50382-2 3600V 400 FX 150°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Plain copper
- Conductor cross-section: 400 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Max. conductor temperature in service: 150 °C
- Overload maximum core temperature: 170 °C
FLAMEX SI EN 50382-2 3600V 50 FX 120°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Tin plated copper
- Conductor cross-section: 50 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Max. conductor temperature in service: 120 °C
- Overload maximum core temperature: 140 °C
FLAMEX SI EN 50382-2 3600V 50 FX 150°C
Nexans ref. 10263127
- Packaging: Drum (1000m)
- Conductor material: Plain copper
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 15.7 mm
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Max. conductor temperature in service: 150 °C
- Overload maximum core temperature: 170 °C
FLAMEX SI EN 50382-2 3600V 6 FX 120°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Tin plated copper
- Conductor cross-section: 6 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Max. conductor temperature in service: 120 °C
- Overload maximum core temperature: 140 °C
FLAMEX SI EN 50382-2 3600V 6 FX 150°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Plain copper
- Conductor cross-section: 6 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Max. conductor temperature in service: 150 °C
- Overload maximum core temperature: 170 °C
FLAMEX SI EN 50382-2 3600V 70 FX 120°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Tin plated copper
- Conductor cross-section: 70 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Max. conductor temperature in service: 120 °C
- Overload maximum core temperature: 140 °C
FLAMEX SI EN 50382-2 3600V 70 FX 150°C
Nexans ref. 10263128
- Packaging: Drum (1000m)
- Conductor material: Plain copper
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 17.3 mm
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Max. conductor temperature in service: 150 °C
- Overload maximum core temperature: 170 °C
FLAMEX SI EN 50382-2 3600V 95 FX 120°C
Nexans ref.
- Packaging: Drum (1000m)
- Conductor material: Tin plated copper
- Conductor cross-section: 95 mm²
- Nominal outer diameter: - mm
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Max. conductor temperature in service: 120 °C
- Overload maximum core temperature: 140 °C
FLAMEX SI EN 50382-2 3600V 95 FX 150°C
Nexans ref. 10263129
- Packaging: Drum (1000m)
- Conductor material: Plain copper
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 18.7 mm
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Max. conductor temperature in service: 150 °C
- Overload maximum core temperature: 170 °C
Description
Description
Standards
-
ProductEN 45545-2 (HL3); EN 50382-2; IEC 60228
DESIGN
1. Conductor
Extra flexible class 6 copper according to IEC 60228
- tinned copper for 120°C Class
- plain copper for 150°C Class
Separator: Unweaved tape
2. Insulation
Cross-linked silicone type EI 111 according to EN 50382-1
Colour: black outer layer
Example of marking: FLAMEX SI - EN 50382-2 - Voltage rate (1800V or 3600V) - cross-section mm² - FX - temperature class (150°C) - LYNXEO 279 - week/year
GUIDE TO USE
- Cabling rules are given in EN 50343 and EN 50355
- Permissible current carrying capacities: values and calculation method are given in EN 50343
- Bending radius:
- Static use: 4 x outer cable diameter
- For installation and occasional movements: 6 x outer cable diameter
- Pulling tensible force (dynamic) during installation: 50 N/mm² of copper size
- Mechanical static tensible force: 15N/mm² of copper size
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Usage characteristics
Usage characteristics
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania