FLAMEX® EN 50382-2 FX

Products

FLAMEX SI EN 50382-2 1800V 10 FX 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 10 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 10 FX 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 10 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 120 FX 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 120 mm²
  • Nominal outer diameter: 20.0 mm
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 120 FX 150°C

Nexans ref. 10227163

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 120 mm²
  • Nominal outer diameter: 20.0 mm
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 150 FX 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 150 mm²
  • Nominal outer diameter: 22.5 mm
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 150 FX 150°C

Nexans ref. 10263103

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 150 mm²
  • Nominal outer diameter: 22.5 mm
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 16 FX 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 16 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 16 FX 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 16 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 185 FX 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 185 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 185 FX 150°C

Nexans ref. 10263125

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 185 mm²
  • Nominal outer diameter: 23.8 mm
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 2.5 FX 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 2.5 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 2.5 FX 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 2.5 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 240 FX 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 240 mm²
  • Nominal outer diameter: 26.7 mm
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 240 FX 150°C

Nexans ref. 10227162

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 240 mm²
  • Nominal outer diameter: 26.7 mm
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 25 FX 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 25 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 25 FX 150°C

Nexans ref. 10261507

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 25 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 300 FX 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 300 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 300 FX 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 300 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 35 FX 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 35 mm²
  • Nominal outer diameter: 13.1 mm
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 35 FX 150°C

Nexans ref. 10261508

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 35 mm²
  • Nominal outer diameter: 13.1 mm
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 4 FX 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 4 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 4 FX 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 4 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 400 FX 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 400 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 400 FX 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 400 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 50 FX 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 50 mm²
  • Nominal outer diameter: 14.4 mm
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 50 FX 150°C

Nexans ref. 10263100

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 50 mm²
  • Nominal outer diameter: 14.4 mm
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 6 FX 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 6 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 6 FX 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 6 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 70 FX 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 70 mm²
  • Nominal outer diameter: 16.4 mm
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 70 FX 150°C

Nexans ref. 10263101

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 70 mm²
  • Nominal outer diameter: 16.4 mm
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 1800V 95 FX 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 95 mm²
  • Nominal outer diameter: 18.3 mm
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 1800V 95 FX 150°C

Nexans ref. 10263102

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 95 mm²
  • Nominal outer diameter: 18.3 mm
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 10 FX 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 10 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 10 FX 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 10 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 120 FX 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 120 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 120 FX 150°C

Nexans ref. 10263130

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 120 mm²
  • Nominal outer diameter: 21.0 mm
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 150 FX 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 150 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 150 FX 150°C

Nexans ref. 10263131

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 150 mm²
  • Nominal outer diameter: 22.3 mm
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 16 FX 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 16 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 16 FX 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 16 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 185 FX 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 185 mm²
  • Nominal outer diameter: 24.6 mm
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 185 FX 150°C

Nexans ref. 10227377

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 185 mm²
  • Nominal outer diameter: 24.6 mm
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 2.5 FX 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 2.5 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 2.5 FX 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 2.5 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 240 FX 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 240 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 240 FX 150°C

Nexans ref. 10263132

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 240 mm²
  • Nominal outer diameter: 28.3 mm
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 25 FX 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 25 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 25 FX 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 25 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 300 FX 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 300 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 300 FX 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 300 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 35 FX 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 35 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 35 FX 150°C

Nexans ref. 10263126

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 35 mm²
  • Nominal outer diameter: 14.0 mm
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 4 FX 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 4 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 4 FX 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 4 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 400 FX 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 400 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 400 FX 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 400 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 50 FX 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 50 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 50 FX 150°C

Nexans ref. 10263127

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 50 mm²
  • Nominal outer diameter: 15.7 mm
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 6 FX 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 6 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 6 FX 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 6 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 70 FX 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 70 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 70 FX 150°C

Nexans ref. 10263128

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 70 mm²
  • Nominal outer diameter: 17.3 mm
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 3600V 95 FX 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 95 mm²
  • Nominal outer diameter: - mm
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 3600V 95 FX 150°C

Nexans ref. 10263129

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 95 mm²
  • Nominal outer diameter: 18.7 mm
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

Description

Description

Standards

  • Product
    EN 45545-2 (HL3); EN 50382-2; IEC 60228

DESIGN

 

1. Conductor
Extra flexible class 6 copper according to IEC 60228
    - tinned copper for 120°C Class
    - plain copper for 150°C Class
Separator: Unweaved tape

2. Insulation
Cross-linked silicone type EI 111 according to EN 50382-1
Colour: black outer layer

Example of marking: FLAMEX SI - EN 50382-2 - Voltage rate (1800V or 3600V) - cross-section mm² - FX - temperature class (150°C) - LYNXEO 279 - week/year

GUIDE TO USE

  • Cabling rules are given in EN 50343 and EN 50355
  • Permissible current carrying capacities: values and calculation method are given in EN 50343
  • Bending radius:
    • Static use: 4 x outer cable diameter
    • For installation and occasional movements: 6 x outer cable diameter
  • Pulling tensible force (dynamic) during installation: 50 N/mm² of copper size
  • Mechanical static tensible force: 15N/mm² of copper size

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor flexibility
Extra-flexible class 6
Insulation
High temperature silicone
Halogen free
EN 60754-1 & EN 60684-2

Usage characteristics

Usage characteristics

Flame retardant
EN 60332-1-2
Fire retardant
EN IEC 60332-3-24 (cat C); EN IEC 60332-3-25 (EN50305)
Smoke density
EN/IEC 61034-2
Gases toxicity
EN 50305-9.2
Operating temperature, range
-50 ... 120 °C
Chemical resistance
Good

Resources

Resources

Documentation

FLAMEX SI type F png — 9.5 kB

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close