FLAMEX® EN 50382-2 FFS
FLAMEX® EN 50382-2 FFS
FLAMEX
SHIELDED HIGH TEMPERATURE FLEXIBLE POWER CABLES
FLAMEX® EN 50382-2 FFS shielded power cables are used for installations where enhanced electrical screening (EMC) is required. Able to withstand higher operating temperatures, these silicone-based cables allow to save cable weight.
FLAMEX DTREN150056 EN 50382-2 1800V 120 FFS 120°C
Nexans ref. 10282209
- Verpackung: Trommel (1000m)
- Leiterquerschnitt: 120 mm²
- Geflechtsquerschnitt: 11,6 mm²
- Nennspannung Uo/U: 1.8 / 3 (3.6) kV
FLAMEX DTREN150056 EN 50382-2 1800V 150 FFS 120°C
Nexans ref. 10282210
- Verpackung: Trommel (1000m)
- Leiterquerschnitt: 150 mm²
- Geflechtsquerschnitt: 12,6 mm²
- Nennspannung Uo/U: 1.8 / 3 (3.6) kV
FLAMEX SI EN 50382-2 3600V 120 FFS 120°C
Nexans ref. 10260431
- Verpackung: Trommel (1000m)
- Leiterquerschnitt: 120 mm²
- Geflechtsquerschnitt: 16,1 mm²
- Nennspannung Uo/U: 3.6 / 6 (7.2) kV
FLAMEX SI EN 50382-2 3600V 150 FFS 120°C
Nexans ref. 10260432
- Verpackung: Trommel (1000m)
- Leiterquerschnitt: 150 mm²
- Geflechtsquerschnitt: 18,3 mm²
- Nennspannung Uo/U: 3.6 / 6 (7.2) kV
FLAMEX SI EN 50382-2 3600V 185 FFS 120°C
Nexans ref. 10260433
- Verpackung: Trommel (1000m)
- Leiterquerschnitt: 185 mm²
- Geflechtsquerschnitt: 18,7 mm²
- Nennspannung Uo/U: 3.6 / 6 (7.2) kV
FLAMEX SI EN 50382-2 3600V 50 FFS 120°C
Nexans ref. 10235715
- Verpackung: Trommel (1000m)
- Leiterquerschnitt: 50 mm²
- Geflechtsquerschnitt: 13,3 mm²
- Nennspannung Uo/U: 3.6 / 6 (7.2) kV
FLAMEX SI EN 50382-2 3600V 70 FFS 120°C
Nexans ref. 10260429
- Verpackung: Trommel (1000m)
- Leiterquerschnitt: 70 mm²
- Geflechtsquerschnitt: 13,5 mm²
- Nennspannung Uo/U: 3.6 / 6 (7.2) kV
FLAMEX SI EN 50382-2 3600V 95 FFS 120°C
Nexans ref. 10260430
- Verpackung: Trommel (1000m)
- Leiterquerschnitt: 95 mm²
- Geflechtsquerschnitt: 15,8 mm²
- Nennspannung Uo/U: 3.6 / 6 (7.2) kV
Beschreibung
Beschreibung
Normen
-
ProduktEN 45545-2 (HL3); EN 50382-2; IEC 60228
DESIGN
1. Conductor
Flexible class 5 copper according to IEC 60228
- tinned copper for 120°C Class
- plain copper for 150°C Class
2. Insulation
Cross-linked silicone type EI 111 according to EN 50382-1
Separator: Unweaved tape
3. Screen
Tinned copper wire braid
Separator: Unweaved tape
4. Outer sheath
Cross-linked silicone type EM 107 according to EN 50382-1
Colour: black outer layer
Examples of marking: FLAMEX SI - EN 50382-2 - Voltage rate (1800V or 3600V) - cross-section mm² - FFS - temperature class (120°C or 150°C) - Manufacturing n° - LYNXEO 279 - week/year
DTREN 150056 - EN 50382-2 - 1800V - cross-section mm² - FFS - temperature class (120°C) - Manufacturing N° - LYNXEO 279 - week/year
GUIDE TO USE
- Cabling rules are given in EN 50343 and EN 50355
- Permissible current carrying capacities: values and calculation method are given in EN 50343
- Bending radius:
- Static use: 10 x outer cable diameter
- For installation and occasional movements: 12 x outer cable diameter
- Pulling tensible force (dynamic) during installation: 50 N/mm² of copper size
- Mechanical static tensible force: 15N/mm² of copper size
Eigenschaften
Eigenschaften
Konstruktionsmerkmale
Konstruktionsmerkmale
Anwendungsmerkmale
Anwendungsmerkmale
Ressourcen
Ressourcen
Unsere Websites
Wählen Sie Ihr Land aus, um unsere Produkte und Lösungen zu finden
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania