FLAMEX® FR TYPE EN 50306-2
FLAMEX® FR TYPE EN 50306-2
FLAMEX
FIRE RESISTANT CONTROL WIRES
FLAMEX® Fire Resistant control wires TYPE EN 50306-2 maintain circuit integrity in case of fire (according to EN 50200 for 120 minutes) and are fire retardant, low smoke and halogenfree safisfying performance requirements of EN 45545-2 HL3. In addition, FLAMEX® cables withstand the tough working conditions of rolling stock (oil, ozone, temperature variations, etc.).
FLAMEX 20 TYPE MSZ 1X0.5
Nexans ref. 13101504
- Leiterquerschnitt: 0,5 mm²
- Conductor diameter (mm): 0.95
- Min. Kabeldurchmesser: 1,7 mm
- Max. Kabeldurchmesser: 2 mm
- Nettogewicht ca.: 7,5 kg/km
FLAMEX 20 TYPE MSZ 1X0.75
Nexans ref. 13112324
- Leiterquerschnitt: 0,75 mm²
- Conductor diameter (mm): 1.15
- Min. Kabeldurchmesser: 1,9 mm
- Max. Kabeldurchmesser: 2,2 mm
- Nettogewicht ca.: 10 kg/km
FLAMEX 20 TYPE MSZ 1X1.0
Nexans ref. 13112325
- Leiterquerschnitt: 1 mm²
- Conductor diameter (mm): 1.30
- Min. Kabeldurchmesser: 2 mm
- Max. Kabeldurchmesser: 2,3 mm
- Nettogewicht ca.: 12,1 kg/km
FLAMEX 20 TYPE MSZ 1X1.5
Nexans ref. 13112327
- Leiterquerschnitt: 1,5 mm²
- Conductor diameter (mm): 1.60
- Min. Kabeldurchmesser: 2,5 mm
- Max. Kabeldurchmesser: 2,9 mm
- Nettogewicht ca.: 18,2 kg/km
FLAMEX 20 TYPE MSZ 1X2.5
Nexans ref. 13101505
- Leiterquerschnitt: 2,5 mm²
- Conductor diameter (mm): 2.00
- Min. Kabeldurchmesser: 2,9 mm
- Max. Kabeldurchmesser: 3,3 mm
- Nettogewicht ca.: 27,6 kg/km
Beschreibung
Beschreibung
Normen
-
ProduktEN 45545-2 (HL3)
-
TestsEN 50200; EN 50305; EN 50306; IEC 60331-2
DESIGN
1. Conductor
Flexible stranded tinned copper
2. Insulation
Mineral tape as fire barrier
Thin wall halogen-free cross-linked material acc. EN 50306-2
Colour: white
Example of marking: FLAMEX 239 - EDE 2PN299 - TYPE EN 50306-2 - EN 50200 - 300 V - 1x0.5 - M - week/year - batch number
GUIDE TO USE
- Cabling rules are given in EN 50343 and EN 50355
- Permissible current carrying capacities: values and calculation method are given in EN 50343
- Bending radius:
- Static use: 5 x outer cable diameter
- For installation and occasional movements: 10 x outer cable diameter
Eigenschaften
Eigenschaften
Konstruktionsmerkmale
Konstruktionsmerkmale
Elektrische Eigenschaften
Elektrische Eigenschaften
Anwendungsmerkmale
Anwendungsmerkmale
Ressourcen
Ressourcen
Unsere Websites
Wählen Sie Ihr Land aus, um unsere Produkte und Lösungen zu finden
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania