FLAMEX® FR TYPE EN 50264-3-1 600V
FLAMEX® FR TYPE EN 50264-3-1 600V
FLAMEX
FIRE RESISTANT POWER CABLES
FLAMEX® EN50264-3-1 FR flexible power cables maintain circuit integrity in case of fire (according to EN 50200 for 90 minutes) and are fire retardant, low smoke and halogen-free safisfying performance requirements of EN 45545-2-HL3. On top of that, FLAMEX® cables withstand tough working conditions (oil, ozone, temperature variations, etc.).
FLAMEX EN50264-3-1 FR (N)MHXAF 0,6/1kV 1x1
Nexans ref. 79462214
- Packaging: Drum (1000m)
- Conductor cross-section: 1 mm²
- Minimum outer diameter: 3.1 mm
- Maximum outer diameter: 3.3 mm
- Approximate weight: 18 kg/km
FLAMEX EN50264-3-1 FR (N)MHXAF 0,6/1kV 1x1.5
Nexans ref. 79462314
- Packaging: Drum (1000m)
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 3.4 mm
- Maximum outer diameter: 3.8 mm
- Approximate weight: 24 kg/km
FLAMEX EN50264-3-1 FR (N)MHXAF 0,6/1kV 1x2.5
Nexans ref. 79462414
- Packaging: Drum (1000m)
- Conductor cross-section: 2.5 mm²
- Minimum outer diameter: 3.8 mm
- Maximum outer diameter: 4.2 mm
- Approximate weight: 33 kg/km
FLAMEX EN50264-3-1 FR (N)MHXAF 0,6/1kV 1x4
Nexans ref. 79462514
- Packaging: Drum (1000m)
- Conductor cross-section: 4 mm²
- Minimum outer diameter: 4.5 mm
- Maximum outer diameter: 4.9 mm
- Approximate weight: 46 kg/km
FLAMEX EN50264-3-1 FR (N)MHXAF 0,6/1kV 1x6
Nexans ref. 79462614
- Packaging: Drum (1000m)
- Conductor cross-section: 6 mm²
- Minimum outer diameter: 5.0 mm
- Maximum outer diameter: 5.4 mm
- Approximate weight: 66 kg/km
FLAMEX EN50264-3-1 FR (N)MHXAF 0,6/1kV 1x10
Nexans ref. 79462714
- Packaging: Drum (1000m)
- Conductor cross-section: 10 mm²
- Minimum outer diameter: 6.1 mm
- Maximum outer diameter: 6.5 mm
- Approximate weight: 110 kg/km
FLAMEX EN50264-3-1 FR (N)MHXAF 0,6/1kV 1x16
Nexans ref. 79462814
- Packaging: Drum (1000m)
- Conductor cross-section: 16 mm²
- Minimum outer diameter: 7.1 mm
- Maximum outer diameter: 7.7 mm
- Approximate weight: 170 kg/km
FLAMEX EN50264-3-1 FR (N)MHXAF 0,6/1kV 1x25
Nexans ref. 79462914
- Packaging: Drum (1000m)
- Conductor cross-section: 25 mm²
- Minimum outer diameter: 8.7 mm
- Maximum outer diameter: 9.3 mm
- Approximate weight: 255 kg/km
FLAMEX EN50264-3-1 FR (N)MHXAF 0,6/1kV 1x35
Nexans ref. 79463014
- Packaging: Drum (1000m)
- Conductor cross-section: 35 mm²
- Minimum outer diameter: 9.8 mm
- Maximum outer diameter: 10.4 mm
- Approximate weight: 340 kg/km
FLAMEX EN50264-3-1 FR (N)MHXAF 0,6/1kV 1x50
Nexans ref. 79463114
- Packaging: Drum (1000m)
- Conductor cross-section: 50 mm²
- Minimum outer diameter: 11.9 mm
- Maximum outer diameter: 12.5 mm
- Approximate weight: 490 kg/km
FLAMEX EN50264-3-1 FR (N)MHXAF 0,6/1kV 1x70
Nexans ref. 79463214
- Packaging: Drum (1000m)
- Conductor cross-section: 70 mm²
- Minimum outer diameter: 13.8 mm
- Maximum outer diameter: 14.4 mm
- Approximate weight: 700 kg/km
FLAMEX EN50264-3-1 FR (N)MHXAF 0,6/1kV 1x95
Nexans ref. 79463314
- Packaging: Drum (1000m)
- Conductor cross-section: 95 mm²
- Minimum outer diameter: 15.3 mm
- Maximum outer diameter: 15.9 mm
- Approximate weight: 900 kg/km
FLAMEX EN50264-3-1 FR (N)MHXAF 0,6/1kV 1x120
Nexans ref. 79463414
- Packaging: Drum (1000m)
- Conductor cross-section: 120 mm²
- Minimum outer diameter: 17.0 mm
- Maximum outer diameter: 17.6 mm
- Approximate weight: 1120 kg/km
FLAMEX EN50264-3-1 FR (N)MHXAF 0,6/1kV 1x150
Nexans ref. 79463514
- Packaging: Drum (1000m)
- Conductor cross-section: 150 mm²
- Minimum outer diameter: 19.2 mm
- Maximum outer diameter: 19.8 mm
- Approximate weight: 1410 kg/km
FLAMEX EN50264-3-1 FR (N)MHXAF 0,6/1kV 1x185
Nexans ref. 79463614
- Packaging: Drum (1000m)
- Conductor cross-section: 185 mm²
- Minimum outer diameter: 21.5 mm
- Maximum outer diameter: 22.1 mm
- Approximate weight: 1710 kg/km
FLAMEX EN50264-3-1 FR (N)MHXAF 0,6/1kV 1x240
Nexans ref. 79463714
- Packaging: Drum (1000m)
- Conductor cross-section: 240 mm²
- Minimum outer diameter: 24.1 mm
- Maximum outer diameter: 24.7 mm
- Approximate weight: 2200 kg/km
Description
Description
Standards
-
ProductBS 6853 cat 1A; EN 50264-3-1; EN 45545 - HL3; GOST-R 31565; IEC 60228
-
TestDIN 5510-2, flame protection class 1-4; EN 50200; IEC 60331-1 or 2; UNI CEI 11170-3
DESIGN
1. Conductor
Flexible stranded tinned copper, class 5 acc. to IEC 60228
Mineral tape
2. Insulation
Cross-linked compound type EI 109 acc. to EN 50264-1
Oil, diesel, ozone and UV resistant
Colour: black
Example of marking: FLAMEX type EN 50264-3-1 FR 600 V mm² M (N)MHXAF-FR 0,6/1kV
I LYNXEO I WW-YYYY
GUIDE TO USE
- Cabling rules are given in EN 50343 and EN 50355
- Permissible current carrying capacities: values and calculation method are given in EN 50343
- Bending radius:
- Static use: 3 x outer cable diameter if D ≤ 10mm / 5 x outer cable diameter if D > 10mm
- For installation and occasional movements: 10 x outer cable diameter
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania