SERVO TRAY CABLES (4G1,5+2x1,5)C

Description

Description

Standards

  • Product
    UL and CSA listing

Approvals

UL MTW

UL TC-ER 90°C 600V

UL WTTC 90°C 1000V

UL DP-1

UL AWM 600V

C(UL) CIC/TC (where required)

 

Oil resistance

Oil resistant I

 

Flame retardant

UL 1581 section 1160 and CSA FT4

 

Nominal Voltage

UL AWM 600V

UL TC-ER / MTW 600V

UL WTTC 1000V

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Construction type
(4G1.5 + (2x1.5)C)C
Conductor material
Soft annealed copper
Insulation
PVC compound
Individual sheath
Nylon jacketing compound
Insulation colour
Power: Black num 1-3 + Green/Yellow; Signal: Black-White
Lay Up
Power conductors and signal pair twisted together. Fillers where required
Taping
Non woven tape
Individual screen
Signal shield: Tinned copper braid, coverage >=80%
Shielding
80% tinned copper braid coverage
Outer sheath
Special PVC compound
Sheath colour
Orange RAL 2003

Dimensional characteristics

Dimensional characteristics

Nominal outer diameter
11.9 mm
Copper content
152 kg/km
Approximate weight
246 kg/km

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U
0.6/1 kV
Test voltage
2000 V

Mechanical characteristics

Mechanical characteristics

Maximum acceleration
10 m/s²
Bending cycles
3 Mio.
Speed
240 m/min

Usage characteristics

Usage characteristics

Field of application
Dynamic
Minimum dynamic operating bending radius
7.5 (xD)
Operating temperature, range
-5 ... 80 °C
Storage temperature, range
-40 ... 80 °C
Oil resistance
Oil resistance I
Flame retardant
UL 1581 SEC. 1160 AND CSA FT4

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close