MEASURING SYSTEM CABLE ACC. TO SIEMENS® STANDARD 6FX5008-DC00 (DRIVE CLiQ)
MEASURING SYSTEM CABLE ACC. TO SIEMENS® STANDARD 6FX5008-DC00 (DRIVE CLiQ)
Measuring systems cables for dynamic application MOTIONLINE®
Read moreDRIVE CLiQ CABLE ACC. TO SIEMENS® STANDARD 6FX5008-2DC00 (2x(2x0,14)C+(2x0,34)C)C
Nexans ref. 44499379 - Country ref. 6FX5008-2DC00
- Packaging: Drum (1000m)
- Construction type: (2x(2x0,14)C+(2x0,34)C)C
- Copper content: 32 kg/km
- Approximate weight: 62 kg/km
DRIVE CLiQ CABLE ACC. TO SIEMENS® 6FX5008-2DC00 (2x(2x0,22)C+(2x0,38)C)C
Nexans ref. 44499779 - Country ref. 6FX5008-2DC00
- Packaging: Drum (1000m)
- Construction type: (2x(2x0,22)C+(2x0,38)C)C
- Copper content: 37 kg/km
- Approximate weight: 66 kg/km
Description
Description
Standards
-
ProductUL and CSA approval
For dynamic applications; PVC Jacket, screened,
resistant to oils and coolants, flame retardant.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Conductor material
Bending-resistant conductor with tinned copper wires
Insulation
TPM with very low capacitance
Insulation colour
1^ Pair: Green+Yellow; 2^ Pair: Pink+Blue
Taping
Copper/Polyester Tape
Screen
Tinned copper braid, coverage ≥ 85%
Outer sheath
PVC
Sheath colour
Grey
Dimensional characteristics
Dimensional characteristics
Outer Diameter
7 mm
Electrical characteristics
Electrical characteristics
Rated Voltage Uo/U
30 V
Test voltage
300 V
Mechanical characteristics
Mechanical characteristics
Maximum acceleration
20 m/s²
Bending cycles
5 Mio.
Speed
180 m/min
Usage characteristics
Usage characteristics
Field of application
Fixed installations
Minimum dynamic operating bending radius
10 (xD)
Operating temperature, range
-15 ... 80 °C
Storage temperature, range
-40 ... 80 °C
Flame retardant
IEC 60332-1-2; UL 1581 FT1
Oil resistance
EN 50363-4-1