HYBRID CABLES ACC. TO HEIDENHAIN HMC6® STANDARD

Products

HYBRID CABLES ACC. TO HEIDENHAIN HMC6® STANDARD (4G1,5+(2x1,0)C+(2x0,24+2x2x0,09)C)C NEW

Nexans ref. 49391760

  • Packaging: Drum (1000m)
  • Construction type: (4G1,5+(2x1,0)C+(2x0,24+2x2x0,09)C)C
  • Outer Diameter: 12.4 mm
  • Copper content: 127 kg/km
  • Approximate weight: 229 kg/km

 

HYBRID CABLES ACC. TO HEIDENHAIN HMC6® STANDARD (4G4,0+(2x1,0)C+(2x0,24+2x2x0,09)C)C NEW

Nexans ref. 49391860

  • Packaging: Drum (1000m)
  • Construction type: (4G4,0+(2x1,0)C+(2x0,24+2x2x0,09)C)C
  • Outer Diameter: 15.1 mm
  • Copper content: 245 kg/km
  • Approximate weight: 365 kg/km

 

Description

Description

Standards

  • Product
    UL and CSA approval

Hybrid cables for servo motors for extremely dynamic applications; PUR Jacket; screened, resistant to oils and coolants, notch resistant, flame retardant, resistant to hydrolysis and microbes, PVC- and halogen-free.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Bending-resistant conductor with bare copper wires
Insulation
TPM with very low capacitance
Insulation colour
Power: Blu-Br-Blk-Gn/Ye; Brake: Wht-Wht/Blk; Supply: Br/Gn - Wht/Gn; Communication: Gry - Pnk - Vio - Ye
Lay Up
power cores and control pairs stranded with filler
Individual screen
Signal shield: Tinned copper braid, coverage >=80%
Screen
Tinned copper braid, coverage ≥ 80%
Inner sheath
TPE compound, optimized for drag chain use
Outer sheath
PUR
Sheath colour
Orange RAL 2003
Halogen free
Yes

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U
0.6/1 kV
Test voltage
4000 V

Mechanical characteristics

Mechanical characteristics

Bending cycles
5 Mio.
Maximum acceleration
50 m/s²
Speed
300 m/min

Usage characteristics

Usage characteristics

Field of application
Dynamic
Minimum dynamic operating bending radius
7.5 (xD)
Operating temperature, range
-30 ... 80 °C
Storage temperature, range
-50 ... 80 °C
Oil resistance
DIN EN 50363-10-2 & DIN EN 60811-404
Flame retardant
IEC 60332-1-2; UL 1581 FT1

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close